<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-07 13-05-53
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 58 dBuV YLEX
Pilot RDS Phase Difference
7.4 kHz 2.2 kHz 57 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 19040 1,1765
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,9 dBr 4,02 dBr 4,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 2 (Affairs) 0 1 1 1 13:05, 7.07.2025
RT
"YleX Etusivu: Teemu Seppänen "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 1,1765 Acquired: 2025/07/07 13.04.49 Total samples: 19040 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 4,8 dBr MIN: 1,9 dBr AVE: 4,02 dBr % above 12,2 dBr: 0,0 Last value: 2,9 dBr (2025/07/07 13.04.49) 12.50 12.52 12.54 12.56 12.58 13.00 13.02 13.04 0 2 4 Pm [dBr]